TEL: +86-13802247168    E-Mail: sales@esunq.cn
 
The solution to the failure of Terminal Insertion Machine
 2023-02-21  360

terminal insertion machine

The solution to the failure of Terminal Insertion Machine.

1. Cannot be skinned.

Solution:
Adjust the stripping value.
Check to see if the skinning Optocoupler is normal.

Solution efficiency: 90%.


2. The terminal insertion machine cannot start normally.

Solution:
Check whether the stroke has reached its zenith.
Whether there are any heavy objects in the take-up slot.

The efficiency of the scheme is 100%.


3. The noise is very loud.

Solution:
Wear occurs between certain parts and parts of the terminal insertion machine, resulting in increased friction.
The screw of the terminal machine is loose in the work, which leads to the jitter of the parts.

The efficiency of the scheme is 100%.


4. The discharge clip can not hold the wire.

Solution:
Turn up the air pressure of the discharge clip.

The efficiency of the scheme is 90%.


5. The leather suction at both ends does not work.

Solution:
Check whether the half-stripping parameter is greater than the thread length in the case of half-peeling at both ends.

The efficiency of the scheme is 100%.


6. Send line deviation alarm.

Solution:
Check whether the straightening wheel is too tight.
Inspect the encoder for damage.

The efficiency of the scheme is 90%.


7. There is a series of hits in the terminal insertion machine.

Solution:
Check whether the switch near the spindle of the terminal insertion machine is damaged or if the screw is loose.
Check whether the circuit board and pedal of the terminal insertion machine are broken.
Check whether the moving rod spring of the terminal insertion machine falls off or breaks and loses elasticity, and whether the moving rod is damaged.
The program is efficient: 100%.

Consult Now:+86-13802247168 Consulting

Online Service >

Contact Us
WhatsAppWhatsApp

Sales Tel

+86-13802247168

E-mail:sales@esunq.cn

WhatsApp