Terminal machine troubleshooting
 2025-06-27  41

1,Electronic wire broken length is not the same 

a. Will be sent to the wire wheel pressed too tight or too loose; adjust the straightener to be able tor have a straightening effect and can be sent to the benchmark. 

b. Disconnect the wound or damage the wound edge; disassemble the new end miling cutter. 

2,Sharpening the mouth length is not the same 

a. Send the wire wheel pressed too tight or loose; with the wire roller adjusting pieces to adjust the gap between the two wheels to the cable line is not squeezed flat and too loose direction. 

b.Cutting and stripping knife selection if shallow or too deep; with the end milling cutter depth adjustment parts to adjust the wound to the appropriate part, in order not to damage the copper core line and can be completely dropped down the set of rubber as a benchmark. 

c.Cutting stripping knife or damage to the wound edge; disassemble the new cutting blade. 

3, the machine and equipment can not start the operation or run when stopped 

a.Check whether there is a current value input (220V) and 6KG tire air pressure standards. 

b.Check the total number of settings have not reached, if reached to be set again after the power-off restart, 

c.Check that there are no cable wires or jammed parts of the operation. 

d.Check the terminal machine there is no signal connection or switching power circuit connection caused by the terminal block machine equipment is not pressed

4,pressed the terminal strip exposed copper heart line unevenly 

a.Check whether the gun-type lower swing arm plastic hose is attached to the cable line; 

b.Check whether the terminal machine wound with the lower swing arm plastic hose is relatively straight 

c. Check whether the terminal machine auxiliary steel cutting is loose.

d. Check the terminal machine and automatic machine in the middle of the interval there is no shift.

5,Terminal machine noise is very big 
Terminal machine present slight noise is all normal situation, if the noise is too much will be: 
a.Terminal machine a component, prefabricated components in the middle of the destruction, resulting in friction expansion; b.Loose screws on the work of the terminal machine, resulting in parts shaking amplitude expansion. 
6, the terminal machine's motor does not turn Check the terminal machine's clutch part is not right, the fuse tube has not been burned out 
7, Terminal machine is now connected
a.Check whether the machine tool spindle bearing nearthe terminal machine power switch is damaged, get to talk about the screws are loose.  
b.Check whether the circuit board of the terminal machine and the pedal board are damaged 
c.Check the terminal machine's dynamic rod popping yellow whether to fall down or crack lack of plasticity, dynamic rod is damaged.  
8, the terminal machine does not reflect a.Check whether the power cord plug of the terminal machine is connected or whether the line appears to be difficult, 
b.Check whether the circuit board of the terminal machine is intact, there is no damagel 
c.Check the terminal machine of each power master switch is not able to use.  
d.Check whether the foot board of the terminal machine has been damaged.  e.Checkthe relay of the terminal machine is not magnetic, there is no destruction